Lighting control measurement

Good light and proper lighting are essential for safe working and preventing accidents not only in the workplace, but also in people's everyday leisure activities. Indoor workplace lighting intensity values are set by law. With the Luxmeter we can easily measure the local intensity of artificial lighting in indoor areas.

lighting measurement

We base this on the following standards and decrees:

  • Decree of the Ministry of Health of the Slovak Republic No. 541/2007 Coll. on details and requirements of lighting at work
  • STN EN 12464-1 Light and lighting. Workplace lighting. Part 1: Indoor workplaces
  • STN EN 12464-2 Workplace lighting. Part 2: Outdoor workplaces
  • STN EN 12193 Light and lighting. Lighting of sports grounds

Table of minimum lighting values by space:

Lighting values by space

Rated illumination (lux)

Warehouses for large objects

50

Warehouses with goods retrieval

100

Warehouses with a reading requirement

200

Toilets

100

Sanitary facilities

500

Engine room

100

Office

500

Drawing rooms

750

Colour control rooms

1000

Assembly and test facilities

1000

Assembly areas for small objects

1500

Data processing facilities

500

Paths in buildings for persons

50

Roads in buildings for vehicles

100

Paths in buildings - staircase

100

Roads in buildings - traffic lanes

100

If you are interested in measuring or have any questions, you can contact us at our email address: reeltech@reeltech.sk or phone number: 0901703235